    Fabricante: Siemens

    CIRCUIT-BREAKER SCREW CONNECTION 10A

    73,72 € excl imposto
    Circuit breaker size S00 for motor protection, CLASS 10 A-release 7...10 A N release 130 A screw terminal Standard switching capacity Circuit breaker SIRIUS 3RV2 For motor protection for the reliable
    SKU: 10305632
    Número de peça do fabricante: 3RV20111JA10
    GTIN: 4011209712492
    Circuit breaker size S00 for motor protection, CLASS 10 A-release 7...10 A N release 130 A screw terminal Standard switching capacity Circuit breaker SIRIUS 3RV2 For motor protection for the reliable shutdown in the event of a short-circuit and for protecting the loads and system against overload, and for safe isolation of the system from the network. Thanks to their low heat loss, the compact and climate-resistant circuit breakers are optimized for use in load feeders, and also for IE3/IE4 motors, of course, and equally for the switching of direct current. Worldwide approvals (e.g. IEC and UL/CSA) and applications in hazardous areas (ATEX or IEC Ex) are a matter of course. Device versions are available for motor protection (also with overload relay function), plant protection, short-circuit protection of starter combinations, transformer protection, as main and EMERGENCY OFF switches and for use in IT networks. They are available with screw or spring-type terminals for fast, maintenance-free and vibration-proof connection, and optionally with integral auxiliary switch. The comprehensive range of accessories, such as auxiliary switches, auxiliary releases, signaling switches etc. is standardized for all sizes. The use of different energy infeed options, such as the associated SIRIUS 3RV29 infeed system, considerably reduces the main circuit wiring. The 3RV2 motor starter protectors replace the well-proven 3RV1 series. Simple, efficient and always up to date - SIRIUS modular system.
    Especificações dos produtos
    Grau de proteção (IP)IP20
    Altura97.0mm
    Largura45.0mm
    Profundidade97.0mm
    Tipo de conexão elétrica do circuito principalTerminal de parafuso
    Construção do dispositivoTécnica de instalação fixa para dispositivo embutido
    Com passagem de subtensão integradaNão
    Tensão nominal de operação690 - 690V
    Potência de operação nominal em AC-3, 230 V2.2kW
    Sensível à falha de faseSim
    Com interruptor auxiliar integradoNão
    Tipo de elemento de controloBotão rotativo
    Faixa de ajuste da disparo em curto-circuito não retardada130 - 130A
    Técnica de disparoMagnético
    Com proteção térmicathermal
    Potência de operação nominal em AC-3, 400 V4.0kW
    Configuração de corrente da proteção contra sobrecargas7 - 10A
    Capacidade de interrupção nominal de curto-circuito lcu a 400 V, CA100.0kA
    Corrente permanente nominal Iu10.0A
    Número de pólos3
    Escreva sua própria avaliação
    • Apenas utilizadores registados podem escrever análises
    *
    *
    • Mau
    • Excelente
    *
    *
    *
    Circuit breaker size S00 for motor protection, CLASS 10 A-release 7...10 A N release 130 A screw terminal Standard switching capacity Circuit breaker SIRIUS 3RV2 For motor protection for the reliable shutdown in the event of a short-circuit and for protecting the loads and system against overload, and for safe isolation of the system from the network. Thanks to their low heat loss, the compact and climate-resistant circuit breakers are optimized for use in load feeders, and also for IE3/IE4 motors, of course, and equally for the switching of direct current. Worldwide approvals (e.g. IEC and UL/CSA) and applications in hazardous areas (ATEX or IEC Ex) are a matter of course. Device versions are available for motor protection (also with overload relay function), plant protection, short-circuit protection of starter combinations, transformer protection, as main and EMERGENCY OFF switches and for use in IT networks. They are available with screw or spring-type terminals for fast, maintenance-free and vibration-proof connection, and optionally with integral auxiliary switch. The comprehensive range of accessories, such as auxiliary switches, auxiliary releases, signaling switches etc. is standardized for all sizes. The use of different energy infeed options, such as the associated SIRIUS 3RV29 infeed system, considerably reduces the main circuit wiring. The 3RV2 motor starter protectors replace the well-proven 3RV1 series. Simple, efficient and always up to date - SIRIUS modular system.
    Especificações dos produtos
    Grau de proteção (IP)IP20
    Altura97.0mm
    Largura45.0mm
    Profundidade97.0mm
    Tipo de conexão elétrica do circuito principalTerminal de parafuso
    Construção do dispositivoTécnica de instalação fixa para dispositivo embutido
    Com passagem de subtensão integradaNão
    Tensão nominal de operação690 - 690V
    Potência de operação nominal em AC-3, 230 V2.2kW
    Sensível à falha de faseSim
    Com interruptor auxiliar integradoNão
    Tipo de elemento de controloBotão rotativo
    Faixa de ajuste da disparo em curto-circuito não retardada130 - 130A
    Técnica de disparoMagnético
    Com proteção térmicathermal
    Potência de operação nominal em AC-3, 400 V4.0kW
    Configuração de corrente da proteção contra sobrecargas7 - 10A
    Capacidade de interrupção nominal de curto-circuito lcu a 400 V, CA100.0kA
    Corrente permanente nominal Iu10.0A
    Número de pólos3